Lorixen.
EN

Chimney Sweep Bookings: Flue, Appliance and Fuel Questions Before the Visit

Short answer: A sweep who books from a bare "name, phone, date" form arrives not knowing whether the job is an open fire, a wood burner with a liner, or a multi-fuel stove behind a register plate. Add five groups of questions: appliance type, fuel, flue route, access and the last sweep. Each answer maps to equipment, visit length or a follow-up call, so the person on the phone is no longer guessing. Keep the form short by showing questions only when an earlier answer makes them relevant.

The owner's question behind every field

Before adding a field, ask what you would do differently with the answer. If the reply would not change your van stock, your timing or your price, leave the field out. Visitors abandon long forms, and a form that asks twelve things about a simple open fire loses the easy jobs.

The sections below are written as the questions a householder or landlord is silently asking, followed by what your form should ask in return.

"What do I have?" Appliance type

Offer pictures, not jargon. Many customers cannot say whether they have a "closed appliance" but they can pick the photo that looks like their fireplace.

Suggested options:

  • Open fire (brick or stone opening)
  • Wood burner or multi-fuel stove (glass door, sits in the opening)
  • Gas fire
  • Range cooker or solid fuel boiler
  • Not sure (with a photo upload)

The "not sure" option matters. It avoids a customer guessing wrong and lets you route the enquiry to a short callback or photo review instead of a confirmed slot.

"What do I burn?" Fuel

Sweeping frequency and the type of deposit differ by fuel, so fuel decides both your advice and your reminder interval later. Offer wood, coal or smokeless fuel, mixed fuel, oil, and "gas". Do not set the interval in the form itself unless you have a policy you are happy to stand behind, as recommendations vary between manufacturers, insurers and local guidance. A neutral line such as "We will confirm how often your set-up needs sweeping at the visit" is honest and keeps you flexible.

If the customer picks gas or oil, consider a note that this booking may need a different registered engineer rather than a sweep. Point to the relevant official register for the trade rather than describing legal duties yourself. In the UK, the Gas Safe Register and the solid fuel registers are the usual places to check who is allowed to do what.

"Where does the smoke go?" Flue route

This is where jobs go wrong. Three short questions cover most of it:

  1. Is there a flue liner? Yes, no, or unknown. A liner changes the brush type and sometimes the method.
  2. Does the chimney go straight up inside the house, or does it run outside? Outside metal flues and twin-wall systems are cleaned differently.
  3. Can you see the cowl or pot from the garden? Ask for a photo of the roofline from the ground. A phone picture takes seconds and tells you pot, cowl, bird guard and approximate height.

If the home is a thatched property or a listed building, add a checkbox for it. You will want to flag the job for the right person before it lands in a standard slot, and these customers expect to be asked.

"Can you get in?" Access and preparation

Fires that are lit the morning of the visit are the single most common reason a sweep cannot start. Put a clear requirement above the date picker: the appliance must be cold, and the room should be clear. A suggested wording is "Please do not light the fire for at least 24 hours before your slot" if that is your own rule, or whichever interval you actually use.

Then collect the practical points:

  • Which floor the fireplace is on
  • Whether there is a clear path from the front door
  • Whether pets will be in the house (a sweep working in a small room needs to know)
  • Whether the roof is needed for a camera inspection or a pot check, and if so whether there is ladder access

Keep these as tick boxes and one free-text line. People write useful things in free text, such as "the key is with the neighbour".

"When was it last done?" History

One dropdown does a lot of work: this year, last year, two or more years ago, never or unknown. Combine it with fuel and you can estimate the likely soot and tar and add time to the slot automatically. For a long gap, you may want an extra buffer in the diary and a heads-up in your confirmation message that the visit could take longer.

Also ask whether the customer has had any trouble: smoke coming back into the room, a smell, a bird nest, or a recent chimney fire. A "problem reported" answer should not drop into the standard queue. Route it to a person who calls back the same day.

Turning answers into a slot length

You do not need software for this at first. A simple table on paper is enough:

Answer combination Suggested handling
Open fire, swept last year, no problems Standard slot
Stove with liner, swept within two years Standard slot plus certificate time
Stove, never swept or unknown Extended slot
Any problem reported Call back before confirming
Unknown appliance Photo request, then confirm

The slot lengths belong to you, so fill them in from your own experience. The point is that the form decides which row a booking falls into without anyone reading the whole message.

After the visit: the paperwork customers keep

Sweeps usually issue a certificate or record. Insurers and letting agents sometimes ask for it, so customers return to search their email. Send it automatically from the same system as the booking: a PDF or a page link, with the date, the appliance, the fuel and your next suggested visit. Attach a photo or two if you took them.

For the reminder, store the next due date as its own field rather than relying on your memory. An automatic message a few weeks before is more useful than a calendar scribble, and it lets customers rebook with one tap.

Making the page findable

Local search matters more than national ranking for this trade. State your service area in plain text, give each main town a short section only if you genuinely cover it, and add LocalBusiness structured data (the field list is in Google's search docs). Show opening hours honestly, because sweeping is seasonal and customers call when they see a closed notice.

FAQ

Should the form show a price?

Only if you can price from the answers. Many sweeps give a "from" price for a standard job and confirm after a photo. Showing a range with a clear note about what pushes it up is better than hiding the cost.

Do I need a photo on every booking?

No. Request one when the appliance is unknown, when the liner status is unknown or when a problem is reported. Standard bookings should not be delayed by a photo step.

How do I handle landlords with several properties?

Let them add more than one address in a single booking and give each address its own appliance block. That saves them re-typing the same details and gives you one invoice contact.

Can customers book a sweep before a stove installation?

Treat that as a separate enquiry type. The installer, not the sweep, usually decides on the liner and the test, so a booking form that assumes a routine visit will mislead them.

We build booking forms like this for trade businesses, so if you would like yours to ask the right questions before anyone drives out, tell us about your sweep rounds.

Sources

WhatsAppBook a call